<LOGO>
FM Transmitter Measurement Report
Created: 2025-11-14 05-14-38
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
99.60 MHz 5/5, 54 dBuV Classic
Pilot RDS Phase Difference
6.8 kHz 3.0 kHz 90 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 63 kHz 18716 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
0,2 dBr 1,45 dBr 2,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"Classic " 62A1 13 (Light M) 1 0 1 1 --:--
RT
"Jousikvartetto Nro 15 G-Duuri D 887 Op. 161 (Schubert) "
AF EON
94.8, 96.2, 99.6, 107.4 MHz -
FM Scope Max at: 63 kHz MIN: 11 kHz % above 76 kHz: 0,0000 Acquired: 2025/11/14 5.13.33 Total samples: 18716 Equivalent time: 0:15:35 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 2,3 dBr MIN: 0,2 dBr AVE: 1,45 dBr % above 12,2 dBr: 0,0 Last value: 1,4 dBr (2025/11/14 5.13.32) 05.00 05.02 05.04 05.06 05.08 05.10 05.12 -1 0 1 2 3 Pm [dBr]